Tohban Report 2012-09-26: Difference between revisions
imported>Hazelbain |
imported>Lglesener No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
{{Infobox Tohban Report| | {{Infobox Tohban Report| | ||
|start_date = 19 | |start_date = 19 Sep 2012 | ||
|end_date = 26 | |end_date = 26 Sep 2012 | ||
|tohban_name = Hazel Bain | |tohban_name = Hazel Bain | ||
|tohban_email = hbain@ssl.berkeley.edu | |tohban_email = hbain@ssl.berkeley.edu | ||
Line 66: | Line 66: | ||
[[Category:Tohban Report 2012]] | |||
[[Category:Tohban Report | |||
Latest revision as of 17:22, 21 March 2013
Tohban Reports | |
---|---|
Start Date: | 19 Sep 2012 |
End Date: | 26 Sep 2012 |
Tohban: | Hazel Bain |
Tohban email: | hbain@ssl.berkeley.edu |
Next Tohban: | Juan Carlos Martinez Oliveros |
List all reports |
Solar Activity
Solar Activity this week was low with only 12 C class flares. There are currently 8 active regions on disk with a forecast of low to intermediate events for the next 48 hours. STEREO B shows a couple of small active regions are due to rotate onto the disk within the next couple of days.
How many GOES flares occurred?
Flares above B, C, M, X class were 9 12 0 0
And how many of these are listed in the RHESSI flare list?
Flares above B, C, M, X class were 7 10 0 0
And how many had EXCELLENT coverage?
Flares above B, C, M, X class were 4 4 0 0
There were RHESSI flares/GOES flares 163 / 21 over the time range 19-Sep-12 26-Sep-12
Memory Management
SSR has been emptying out at the end of the pass set.
Spacecraft Status
Cold plates 1 and 2 are currently sitting at 107.9 and 106.4 K respectively.
Data Gaps
There were only 2 short 5 minute data gaps on the 21st of September.
Detector issues
The HV on detector 8 was lowered by 6 steps to 3554 V at 2012-09-21 15:59:51 UT. However it still shows a slower day coming out of the SAA than other detectors.
Spacecraft Management
Decimation | Active/vigorous |
HLAT Decimation | Rear decimation weight 6, no front decimation |
Night time data (fronts) | +/- 4 minutes |
Night time data (rears) | +/- 4 minutes |
Require extra passes? | No |
Requirement for moving pointer? | No |
Attenuator operation | Normal |
Detector problems? | HV on detector 8 was lowered by 6 steps. |