Weekly Report 17Sep2010: Difference between revisions
imported>Agopie No edit summary |
imported>Agopie No edit summary |
||
| Line 1: | Line 1: | ||
===Imaging the Albedo with Pixon=== | ===Imaging the Albedo with Pixon=== | ||
The following show Pixon images for simulated data of a point source with albedo. Each image shows the contours for the Pixon reconstruction overlaid on the a map of the original data. Below each image are the profiles for the data and the fit showing the C statistic for each detector. For each image the following parameters were used: | |||
Time: 2-September-2002 00:07:36 - 00:08:20 | |||
Detectors: All Detectors | |||
Image Size: 64 X 64 | |||
Pixel Size: .5 X .5 | |||
Above each image is the total counts in the final image. Below each image is the source size data as calculated using the 3 sigma source size program written by Rick Pernak. | |||
====Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 301 arcsec and Y = 0.0==== | |||
The total counts in the final image below is: ~10e4 counts | |||
[[Image: | [[Image:Org data 301 10e4 cont.jpg|center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e4]] | ||
The 3 sigma parameters for the reconstructed image assuming an elliptical source are: | |||
Source Flux: 32.0174 | |||
Source X: 301.042 | |||
Source Y: -0.0517814 | |||
Source FWHM: 4.71759 | |||
Eccentricity: 0.253152 | |||
Source Angle: 90.0000 | |||
[[Image:Pixon cstat profile sim 301 10e5.jpg|center|thumb|600px|]] | |||
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector. | |||
[[Image:Pixon cstat profile sim 301 10e4.jpg |center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]] | |||
The total counts in the final image below is: ~10e5 counts | |||
[[Image:Org data 301 10e5 cont.jpg |center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e5]] | |||
The 3 sigma parameters for the reconstructed image assuming an elliptical source are: | |||
Source Flux: 310.592 | |||
Source X: 301.157 | |||
Source Y: -0.344853 | |||
Source FWHM: 3.94633 | |||
Eccentricity: 0.0599250 | |||
Source Angle: 107.000 | |||
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector. | |||
[[Image:Pixon cstat profile sim 301 1x10e5.jpg |center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]] | |||
The total counts in the final image below is: ~10e6 | |||
[[Image:Org data 301 10e6 cont.jpg |center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e6]] | |||
The 3 sigma parameters for the reconstructed image assuming an elliptical source are: | |||
Source Flux: 1473.15 | |||
Source X: 301.232 | |||
Source Y: -0.429101 | |||
Source FWHM: 4.42663 | |||
Eccentricity: 0.260343 | |||
Source Angle: 167.000 | |||
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector. | |||
[[Image:Pixon cstat profile sim 301 10e5.jpg|center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]] | |||
[[Image:Profiles 301.jpg |center|thumb|600px|]] | [[Image:Profiles 301.jpg |center|thumb|600px|]] | ||
====Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 929 arcsec and Y = 0.0==== | |||
[[Image:Org data 930 10e4 cont.jpg |center|thumb|600px|]] | [[Image:Org data 930 10e4 cont.jpg |center|thumb|600px|]] | ||
Revision as of 16:48, 19 September 2010
Imaging the Albedo with Pixon
The following show Pixon images for simulated data of a point source with albedo. Each image shows the contours for the Pixon reconstruction overlaid on the a map of the original data. Below each image are the profiles for the data and the fit showing the C statistic for each detector. For each image the following parameters were used: Time: 2-September-2002 00:07:36 - 00:08:20 Detectors: All Detectors Image Size: 64 X 64 Pixel Size: .5 X .5
Above each image is the total counts in the final image. Below each image is the source size data as calculated using the 3 sigma source size program written by Rick Pernak.
Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 301 arcsec and Y = 0.0
The total counts in the final image below is: ~10e4 counts
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
Source Flux: 32.0174 Source X: 301.042 Source Y: -0.0517814 Source FWHM: 4.71759 Eccentricity: 0.253152 Source Angle: 90.0000
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.
The total counts in the final image below is: ~10e5 counts
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
Source Flux: 310.592 Source X: 301.157 Source Y: -0.344853 Source FWHM: 3.94633 Eccentricity: 0.0599250 Source Angle: 107.000
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.
The total counts in the final image below is: ~10e6
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
Source Flux: 1473.15 Source X: 301.232 Source Y: -0.429101 Source FWHM: 4.42663 Eccentricity: 0.260343 Source Angle: 167.000
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.