===Imaging the Albedo with Pixon===
===Imaging the Albedo with Pixon===


[[Image:Org data 301 10e4 cont.jpg‎‎|center|thumb|600px|]]
The following show Pixon images for simulated data of a point source with albedo. Each image shows the contours for the Pixon reconstruction overlaid on the a map of the original data.  Below each image are the profiles for the data and the fit showing the C statistic for each detector. For each image the following parameters were used:
Time: 2-September-2002 00:07:36 - 00:08:20
Detectors: All Detectors
Image Size: 64 X 64
Pixel Size: .5 X .5


[[Image:Pixon cstat profile sim 301 10e4.jpg‎ |center|thumb|600px|]]
Above each image is the total counts in the final image. Below each image is the source size data as calculated using the 3 sigma source size program written by Rick Pernak.  


[[Image:Org data 301 10e5 cont.jpg‎ |center|thumb|600px|]]


====Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 301 arcsec and Y = 0.0====
The total counts in the final image below is: ~10e4 counts


[[Image:Pixon cstat profile sim 301 1x10e5.jpg‎ ‎|center|thumb|600px|]]
[[Image:Org data 301 10e4 cont.jpg‎‎|center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e4]]


[[Image:Org data 301 10e6 cont.jpg‎ |center|thumb|600px|]]
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
  Source Flux:  32.0174
  Source X:    301.042
  Source Y:    -0.0517814
  Source FWHM:  4.71759
  Eccentricity: 0.253152
  Source Angle: 90.0000


[[Image:Pixon cstat profile sim 301 10e5.jpg‎|center|thumb|600px|]]
 
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.
[[Image:Pixon cstat profile sim 301 10e4.jpg‎ |center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]]
 
 
The total counts in the final image below is: ~10e5 counts
[[Image:Org data 301 10e5 cont.jpg‎ |center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e5]]
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
  Source Flux:  310.592
  Source X:      301.157
  Source Y:      -0.344853
  Source FWHM:  3.94633
  Eccentricity:  0.0599250
  Source Angle:  107.000
 
 
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.
[[Image:Pixon cstat profile sim 301 1x10e5.jpg‎ ‎|center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]]
 
The total counts in the final image below is: ~10e6
[[Image:Org data 301 10e6 cont.jpg‎ |center|thumb|600px|The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e6]]
The 3 sigma parameters for the reconstructed image assuming an elliptical source are:
Source Flux:  1473.15
Source X:    301.232
Source Y:    -0.429101
Source FWHM:  4.42663
Eccentricity: 0.260343
Source Angle: 167.000
 
 
The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.
[[Image:Pixon cstat profile sim 301 10e5.jpg‎|center|thumb|600px|The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.]]


[[Image:Profiles 301.jpg‎ |center|thumb|600px|]]
[[Image:Profiles 301.jpg‎ |center|thumb|600px|]]


 
====Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 929 arcsec and Y = 0.0====
[[Image:Org data 930 10e4 cont.jpg‎‎ |center|thumb|600px|]]
[[Image:Org data 930 10e4 cont.jpg‎‎ |center|thumb|600px|]]



Revision as of 16:48, 19 September 2010

Imaging the Albedo with Pixon

The following show Pixon images for simulated data of a point source with albedo. Each image shows the contours for the Pixon reconstruction overlaid on the a map of the original data. Below each image are the profiles for the data and the fit showing the C statistic for each detector. For each image the following parameters were used: Time: 2-September-2002 00:07:36 - 00:08:20 Detectors: All Detectors Image Size: 64 X 64 Pixel Size: .5 X .5

Above each image is the total counts in the final image. Below each image is the source size data as calculated using the 3 sigma source size program written by Rick Pernak.


Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 301 arcsec and Y = 0.0

The total counts in the final image below is: ~10e4 counts

The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e4

The 3 sigma parameters for the reconstructed image assuming an elliptical source are:

 Source Flux:  32.0174
 Source X:     301.042
 Source Y:     -0.0517814
 Source FWHM:  4.71759
 Eccentricity: 0.253152
 Source Angle: 90.0000 


The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.

The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.


The total counts in the final image below is: ~10e5 counts

The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e5

The 3 sigma parameters for the reconstructed image assuming an elliptical source are:

 Source Flux:   310.592
 Source X:      301.157
 Source Y:      -0.344853
 Source FWHM:   3.94633
 Eccentricity:  0.0599250
 Source Angle:  107.000


The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.

The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.

The total counts in the final image below is: ~10e6

The original data map with the contours of the Pixon Image overlaid for an eventlist with total counts ~10e6

The 3 sigma parameters for the reconstructed image assuming an elliptical source are:

Source Flux:  1473.15
Source X:     301.232
Source Y:     -0.429101
Source FWHM:  4.42663
Eccentricity: 0.260343
Source Angle: 167.000


The following plot shows the profile for each detector compared with the fitted profile along with the C statistic for each detector.

The profile for each detector along with the fitted profile from Pixon. The C statistic for each detector is also shown.
Profiles 301.jpg

Reconstructed Pixon Images for a point source with albedo located at heliocentric X = 929 arcsec and Y = 0.0

Org data 930 10e4 cont.jpg
Pixon cstat profile sim 930 10e4.jpg
Org data 930 10e5 cont.jpg
Pixon cstat profile sim 930 10e5.jpg
Org data 930 10e6 cont.jpg
Pixon cstat profile sim 930 10e6.jpg
Profiles 929.jpg