The following plots are extensions of the plots from the [[Weekly Report 12Nov2010|previous report]].
The following plots are extensions of the plots from the [[Weekly Report 12Nov2010|previous report]].


The plot below shows the gaussian model of the compact source (orange),  
The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan)for a source near disk center.
[[File:Flux 301 high avg min max.jpg|center|thumb|600px|]]
[[File:Flux 301 high avg min max.jpg|center|thumb|600px|Original Data Map (Black), Pixon Map (Purple), Clean Map (Cyan), Model Gaussian (orange) for a source near the disk center]]


[[File:Flux 931 high avg min max.jpg|center|thumb|600px|]]
 
 
The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan) for a source near the limb.
[[File:Flux 931 high avg min max.jpg|center|thumb|600px|Original Data Map (Black), Pixon Map (Purple), Clean Map (Cyan), Model Gaussian (orange for a source near the limb)]]


[[File:Clean limb disk.jpg|center|thumb|600px|]]
[[File:Clean limb disk.jpg|center|thumb|600px|]]

Revision as of 18:47, 23 November 2010

Pixon Albedo Imaging

Using Eduard Kontar's simulated eventlist files, Pixon Images were created for a compact circular gaussian source with an albedo contribution near disk center, and near the limb. The following parameters were used for each image:

  • Time: 2-Sep-2002 00:07:36 - 00:08:16
  • Energy 24keV - 51keV
  • Detectors 1 to 4
  • Image Size: 64 by 64 pixels
  • Pixel Size: .5 arcsec by .5 arcsec

The following plots are extensions of the plots from the previous report.

The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan)for a source near disk center.

Original Data Map (Black), Pixon Map (Purple), Clean Map (Cyan), Model Gaussian (orange) for a source near the disk center


The plot below shows the gaussian model of the compact source (orange),the original data map with the minimum and maximum value at each radial distance (Black), the Pixon image with the minimum and maximum value at each radial distance (Purple), and the clean image with the minimum and maximum value at each radial distance (Cyan) for a source near the limb.

Original Data Map (Black), Pixon Map (Purple), Clean Map (Cyan), Model Gaussian (orange for a source near the limb)
Clean limb disk.jpg
Pixon limb disk.jpg


RHESSI Image Test - Clean v. Pixon

Two sources same flux cl pix.jpg
Flux 301 low avg.jpg
Flux 301 low avg.jpg

RHESSI Website Migration