Weekly Report 8Apr2011: Difference between revisions
imported>Agopie No edit summary |
imported>Agopie No edit summary |
||
Line 8: | Line 8: | ||
*Clean Beam Width Factor = 2 | *Clean Beam Width Factor = 2 | ||
For each energy range (12keV-25keV and 25keV-50keV) an image was made for each detector combination. Using the images the flux was measured for detector | For each energy range (12keV-25keV and 25keV-50keV) an image was made for each detector combination. Using the images the flux was measured for each detector combination. The centroids of each source was also measured. The differences in the centroid location were recorded to give the displacement of a compact or extended source from the complete source. In the final case the ratio of the flux in the extended sources in the 25keV-50keV band was taken with that of the compact source for the same flare in the 12keV-25keV band. | ||
A discussion of all plots as a group follows below the final plot. | |||
[[File:DiffvsDistance 2003 15 25 detcom1 detcom0.jpg|center|thumb|700px|]] | The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 2-6 in the 12keV-25keV energy band. | ||
[[File:DiffvsDistance 2003 15 25 detcom1 detcom0.jpg|center|thumb|700px|The plot shows the difference in centroids of a source imaged using detectors 2-6 and detectors 3-9 plotted versus the distance to the flare from the sun disc center.]] | |||
[[File:DiffvsDistance 2003 15 25 detcom2 detcom0.jpg |center|thumb|700px|]] | The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 6-9 in the 12keV-25keV energy band. | ||
[[File:DiffvsDistance 2003 15 25 detcom2 detcom0.jpg |center|thumb|700px|The plot shows the difference in centroids of a source imaged using detectors 6-9 and detectors 3-9 plotted versus the distance to the flare from the sun disc center.]] | |||
[[File:Diff dist 25to50 dcob1 minus dcomb0.jpg|center|thumb|700px|]] | The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 2-6 in the 25keV-50keV energy band. | ||
[[File:Diff dist 25to50 dcob1 minus dcomb0.jpg|center|thumb|700px|The plot shows the difference in centroids of a source imaged using detectors 2-6 and detectors 3-9 plotted versus the distance to the flare from the sun disc center.]] | |||
[[File:Dif dist 25to50 dcomb2 minus dcomb0.jpg|center|thumb|700px|]] | The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 6-9 in the 25keV-50keV energy band. | ||
[[File:Dif dist 25to50 dcomb2 minus dcomb0.jpg|center|thumb|700px|The plot shows the difference in centroids of a source imaged using detectors 6-9 and detectors 3-9 plotted versus the distance to the flare from the sun disc center.]] | |||
The plot below shows the ratio of the flux in the extended source in the 25keV - 50keV band divided by the flux in the 12kev - 25keV band. | |||
[[File:DiffvsDistance 2003 15 25 50 ratio.jpg|center|thumb|700px|]] | [[File:DiffvsDistance 2003 15 25 50 ratio.jpg|center|thumb|700px|The plot below shows the ratio of the flux in detectors]] |
Revision as of 00:12, 12 April 2011
RHESSI Albedo Imaging Test
RHESSI Clean Imaging techniques were used to image large groups of flares using different detector combinations and energy ranges. The following were used to create the Clean images:
- Time: Decided by the peak of a flare in the 25keV - 50keV range
- Energy: 12kev - 25keV, or 25keV - 50KeV
- Detectors: 3 to 9, or 3 to 6, or 6 to 9
- Clean Beam Width Factor = 2
For each energy range (12keV-25keV and 25keV-50keV) an image was made for each detector combination. Using the images the flux was measured for each detector combination. The centroids of each source was also measured. The differences in the centroid location were recorded to give the displacement of a compact or extended source from the complete source. In the final case the ratio of the flux in the extended sources in the 25keV-50keV band was taken with that of the compact source for the same flare in the 12keV-25keV band.
A discussion of all plots as a group follows below the final plot.
The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 2-6 in the 12keV-25keV energy band.
The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 6-9 in the 12keV-25keV energy band.
The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 2-6 in the 25keV-50keV energy band.
The plot below shows the difference in distance of the centroids using detectors 3-9 versus detectors 6-9 in the 25keV-50keV energy band.
The plot below shows the ratio of the flux in the extended source in the 25keV - 50keV band divided by the flux in the 12kev - 25keV band.