imported>Lglesener (Created page with "Detector 9 history/issues goes here.") |
imported>Hazelbain No edit summary |
||
| Line 1: | Line 1: | ||
* 15 Feb 2012: Final stages of the anneal, all detectors, are back to 4000 V, except for detector 9 (which showed some arcing after SAA passages). | |||
* 7 - 14 March 2012: Some noise was observed on detector 9. On March 8 at 01:24 UTC detector G9 HV was lowered by ten counts. Some sporadic noise was observed, but the detector appears to fixed it-self. | |||
* 11 - 18 April 2012: | |||
** Rear fast threshold from 0x45 -> 0x60 | |||
*** /IDPUDUMPTABL DIBTBL9 | |||
*** /IDPUTABLE9 REARFASTDAC ;Load address 0x262C | |||
*** /IDPULOAD VALUE=0x60 ;Byte 10, Rear Fast threshold | |||
Revision as of 06:27, 5 September 2012
- 15 Feb 2012: Final stages of the anneal, all detectors, are back to 4000 V, except for detector 9 (which showed some arcing after SAA passages).
- 7 - 14 March 2012: Some noise was observed on detector 9. On March 8 at 01:24 UTC detector G9 HV was lowered by ten counts. Some sporadic noise was observed, but the detector appears to fixed it-self.
- 11 - 18 April 2012:
- Rear fast threshold from 0x45 -> 0x60
- /IDPUDUMPTABL DIBTBL9
- /IDPUTABLE9 REARFASTDAC ;Load address 0x262C
- /IDPULOAD VALUE=0x60 ;Byte 10, Rear Fast threshold
- Rear fast threshold from 0x45 -> 0x60