Tohban Report 2017-03-01: Difference between revisions
imported>Pshilaire |
imported>Pshilaire No edit summary |
||
Line 129: | Line 129: | ||
...but it looks like we will need another increase as soon as we get monitor rate information during the above change. | ...but it looks like we will need another increase as soon as we get monitor rate information during the above change. | ||
== Memory Management == | |||
It looks like D6 page has not been updated: its voltage still indicated to be zero currently! | |||
== Notes == | == Notes == |
Revision as of 18:11, 1 March 2017
Tohban Reports | |
---|---|
Start Date: | 22 February 2017 |
End Date: | 1 March 2017 |
Tohban: | Pascal Saint-Hilaire |
Tohban email: | pascal@ssl.berkeley.edu |
Next Tohban: | TBD |
List all reports |
Solar Activity
This week was quiet, aside for two high-B flares on Sunday and Monday.
How many GOES flares occurred?
Flares above B, C, M, X class were 17 3 0 0
And how many of these are listed in the RHESSI flare list?
Flares above B, C, M, X class were 9 3 0 0
And how many had EXCELLENT coverage?
Flares above B, C, M, X class were 4 1 0 0
There were RHESSI flares/GOES flares 17 / 20 over the time range 21-Feb-17 28-Feb-17
Memory Management
Memory seems steady at ~25% at end of pass daily set.
Decimation was normal/vigorous. [Why not quiet/vigorous, so we do not decimate?]
BGS station is still in the red for downlink. Still unclear what the issue is. This means we never know when what the monitor rates are until a few days after the fact, unless we specifically ask for VC2 dumps. Perhaps we sould have them automatically while BGS is down?
Spacecraft Status
D3 and D6 are on. Cryocooler power is still at 75W.
From Nicole's notes last week: The background flux is up at 12%, and the out shutter is set to ~15%. We still have margin, but Ops suggest that we adjust this. The idea is that we will raise the thin shutter out threshold to 5% above the current deadtime, so we will raise it to ~17%. ==> I have seen almost 16% on the status page.
17-053-23:39:39 start attenuator013_bg ; set to 16.5%
17-053-23:39:50 /IDPULOAD VALUE=0 ; 0 Min A0 17-053-23:39:50 /IDPULOAD VALUE=55 ; 21.5686 Max A0 17-053-23:39:50 /IDPULOAD VALUE=46 ; 18.03922 Min A1 17-053-23:39:50 /IDPULOAD VALUE=60 ; 23.5294 Max A1 17-053-23:39:50 /IDPULOAD VALUE=44 ; 17.2549 Min A2 17-053-23:39:50 /IDPULOAD VALUE=80 ; 31.3725 Max A2 17-053-23:39:50 /IDPULOAD VALUE=48 ; 18.8235 Min A3 17-053-23:39:50 /IDPULOAD VALUE=255 ; 100 Max A3
17-053-23:42:06 start show_temps_avg 17-053-23:42:24 CP1: 365.5 K 17-053-23:42:24 CP2: 365.0 K 17-053-23:42:24 CT1: 356.7 K 17-053-23:42:24 CT2: 355.9 K 17-053-23:42:24 TST: 378.4 K 17-053-23:42:24 cp1 - ct1 = 24.41 K 17-053-23:42:24 Cryo Power: 27.5 W 17-053-23:42:24 Cryo Accel: 3.37 mG
Data Gaps
Only VC3 data gaps of import is 2017-02-23T00:10:00.000 -- 2017-02-23T02:20:00.000 7800.0000
DATA GAPS FOR 2017/02/22 TIME RANGE: 2017-02-22T00:00:00.000 -- 2017-02-23T00:00:00.000 GAPS IN APP_ID = 1 (VC1-SOH) WITH PACKET RATE LT 30 N_GAPS 1 GAP START TIME GAP END TIME GAP (SEC) 2017-02-22T18:35:00.000 -- 2017-02-22T22:10:00.000 12900.000 GAPS IN APP_ID = 154 (VC1-PMTRAS) WITH PACKET RATE LT 4 N_GAPS 1 GAP START TIME GAP END TIME GAP (SEC) 2017-02-22T18:35:00.000 -- 2017-02-22T22:05:00.000 12600.000 GAPS IN APP_ID = 102 (VC3-MONITOR RATES) WITH PACKET RATE LT 30 N_GAPS 1 GAP START TIME GAP END TIME GAP (SEC) 2017-02-22T06:05:00.000 -- 2017-02-22T06:15:00.000 600.00000
DATA GAPS FOR 2017/02/23 TIME RANGE: 2017-02-23T00:00:00.000 -- 2017-02-24T00:00:00.000 NO GAPS IN APP_ID = 1 (VC1-SOH) NO GAPS IN APP_ID = 154 (VC1-PMTRAS) GAPS IN APP_ID = 102 (VC3-MONITOR RATES) WITH PACKET RATE LT 30 N_GAPS 3 GAP START TIME GAP END TIME GAP (SEC) 2017-02-23T00:00:00.000 -- 2017-02-23T00:05:00.000 300.00000 2017-02-23T00:10:00.000 -- 2017-02-23T02:20:00.000 7800.0000 !!!!!!!!!!!!!!!!!!!!!!!!!! 2017-02-23T16:25:00.000 -- 2017-02-23T16:30:00.000 300.00000
DATA GAPS FOR 2017/02/24 TIME RANGE: 2017-02-24T00:00:00.000 -- 2017-02-25T00:00:00.000 GAPS IN APP_ID = 1 (VC1-SOH) WITH PACKET RATE LT 30 N_GAPS 2 GAP START TIME GAP END TIME GAP (SEC) 2017-02-24T14:40:00.000 -- 2017-02-24T15:10:00.000 1800.0000 2017-02-24T16:20:00.000 -- 2017-02-24T16:25:00.000 300.00000 GAPS IN APP_ID = 154 (VC1-PMTRAS) WITH PACKET RATE LT 4 N_GAPS 1 GAP START TIME GAP END TIME GAP (SEC) 2017-02-24T17:20:00.000 -- 2017-02-24T17:35:00.000 900.00000 NO GAPS IN APP_ID = 102 (VC3-MONITOR RATES)
Detector issues
D6f livetime has been dropping fairly fast. F6f fast thresholds were commanded from 0x90 to 0xB0 on Feb 28th:
17-059-20:49:32 start idib_chg_thrshld(6,FRONT,FAST,0xB0) 17-059-20:49:36 /IDPUDUMPTABL TABLE=DIBTBL6 17-059-20:49:36 /IDPUTABLE6 OFFSET=FRONTFASTDAC 17-059-20:49:48 /IDPULOAD VALUE=0xB0 ; was 0x90
17-059-20:50:06 start show_temps_avg 17-059-20:50:24 CP1: 154.5 K 17-059-20:50:24 CP2: 153.1 K 17-059-20:50:24 CT1: 130.0 K 17-059-20:50:24 CT2: 128.2 K 17-059-20:50:24 TST: 190.0 K 17-059-20:50:24 cp1 - ct1 = 24.44 K 17-059-20:50:24 Cryo Power: 75.5 W 17-059-20:50:24 Cryo Accel: 12.1 mG
...but it looks like we will need another increase as soon as we get monitor rate information during the above change.
Memory Management
It looks like D6 page has not been updated: its voltage still indicated to be zero currently!
Notes
Spacecraft Management
Decimation | Normal/Vigorous |
HLAT Decimation | Rear decimation |
Night time data (fronts) | plus/minus 4 minutes from daylight |
Night time data (rears) | plus/minus 4 minutes from daylight |
Require extra passes? | No |
Requirement for moving pointer? | Yes |
Attenuator operation | Commanded out |
Detector problems? | See notes above. |