Tohban Report 2018-02-28
Tohban Reports | |
---|---|
Start Date: | 21 February 2018 |
End Date: | 28 February 2018 |
Tohban: | Jim McTiernan |
Tohban email: | jimm@ssl.berkeley.edu |
Next Tohban: | TBD |
List all reports |
Solar Activity
Quiet...
How many GOES flares occurred?
Flares above B, C, M, X class were 2 0 0 0
RHESSI flare list contains 0 over the time range 20-Feb-18 27-Feb-18
No overlapping RHESSI flares to count.
Memory Management
Decimation was active/vigorous for the full time period, SSR fill was between 62 and 25%. Currently the SSR fill is approximately 25% at the end of passes each day.
Spacecraft Status
Detectors 3 and 8 are recording events. The cold tips are 133.8 and 132.1 K as of 25-Feb-2018. The cold plates, 1 and 2 are 158.8 and 157.3 K. Cryocooler power is 64.4W, cryocooler efficiencies are 0.0297 and 0.0300. See:
http://sprg.ssl.berkeley.edu/~ayshih/soh/latest_temperatures.pdf
for a summary plot of recent temperatures, efficiencies and accelerometer values.
Data Gaps
DATA GAPS FOR 20-feb-2018 TO 28-feb-2018
TIME RANGE: 2018-02-20T00:00:00.000 -- 2018-02-28T00:00:00.000 GAPS IN APP_ID = 1 (VC1-SOH) WITH PACKET RATE LT 30 N_GAPS 1 GAP START TIME GAP END TIME GAP (SEC) 2018-02-20T20:45:00.000 -- 2018-02-20T21:05:00.000 1200.0000 GAPS IN APP_ID = 154 (VC1-PMTRAS) WITH PACKET RATE LT 4 N_GAPS 5 GAP START TIME GAP END TIME GAP (SEC) 2018-02-20T15:00:00.000 -- 2018-02-20T15:35:00.000 2100.0000 2018-02-20T20:45:00.000 -- 2018-02-20T21:00:00.000 900.00000 2018-02-21T07:05:00.000 -- 2018-02-21T15:05:00.000 28800.000 2018-02-23T15:10:00.000 -- 2018-02-23T17:30:00.000 8400.0000 2018-02-26T13:35:00.000 -- 2018-02-26T16:00:00.000 8700.0000 GAPS IN APP_ID = 102 (VC3-MONITOR RATES) WITH PACKET RATE LT 30 N_GAPS 0
Detector issues
Detectors 3 and 8 are powered on, and are recording events. No threshold changes or HV changes this past week.
Spacecraft Management
Decimation | Active/Vigorous |
HLAT Decimation | Rear decimation |
Night time data (fronts) | plus/minus 4 minutes from daylight |
Night time data (rears) | plus/minus 4 minutes from daylight |
Require extra passes? | No |
Requirement for moving pointer? | No |
Attenuator operation | Nominal |
Ref. deadtime for Att.thresholds | 28.x% |
Detector problems? | See above |